<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-18 11-10-13
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.70 MHz 5/5, 60 dBuV N.DAME
Pilot RDS Phase Difference
7.0 kHz 3.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
19 kHz 74 kHz 9990 0,2102
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
5,3 dBr 5,62 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" N.DAME " FE32 0 (No PTY) 0 0 1 2 11:10, 18.03.2025
RT
"La Vie prend un sens. J'ecoute, je donne. radionotredame.com "
AF EON
90.7, 100.7 MHz -
FM Scope Station: 100.70 MHz, signal: 5/5 (59 dBuV) Max at: 74 kHz MIN: 19 kHz % above 76 kHz: 0,2102 Acquired: 2025/03/18 11:09:09 Total samples: 9990 Equivalent time: 0:08:19 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 5,9 dBr MIN: 5,3 dBr AVE: 5,62 dBr % above 10,2 dBr: 0,0 Last value: 5,5 dBr (2025/03/18 11:09:09) Station: 100.70 MHz, signal: 4/5 (60 dBuV) 11:02 11:03 11:04 11:05 11:06 11:07 11:08 11:09 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality